Simultaneous nitrogen and organics removal using membrane aeration and effluent ultrafiltration in an anaerobic fluidized membrane bioreactor

Y. Ye, P.E. Saikaly, B.E. Logan
Bioresource Technology, volume 244, pp. 456-462, (2017)

Simultaneous nitrogen and organics removal using membrane aeration and effluent ultrafiltration in an anaerobic fluidized membrane bioreactor

Keywords

Membrane aerator, Nitrogen nutrient removal, Anaerobic fluidized bed membrane bioreactor

Abstract

​Dissolved methane and a lack of nutrient removal are two concerns for treatment of wastewater using anaerobic fluidized bed membrane bioreactors (AFMBRs). Membrane aerators were integrated into an AFMBR to form an aeration membrane fluidized bed membrane bioreactor (AeMFMBR) capable of simultaneous removal of organic matter and ammonia without production of dissolved methane. Good effluent quality was obtained with no detectable suspended solids, 93 ± 5% of chemical oxygen demand (COD) removal to 14 ± 11 mg/L, and 74 ± 8% of total ammonia (TA) removal to 12 ± 3 mg-N/L for domestic wastewater (COD of 193 ± 23 mg/L and TA of 49 ± 5 mg-N/L) treatment. Nitrate and nitrite concentrations were always low (<1 mg-N/L) during continuous flow treatment. Membrane fouling was well controlled by fluidization of the granular activated carbon (GAC) particles (transmembrane pressures maintained <3 kPa). Analysis of the microbial communities suggested that nitrogen removal was due to nitrification and denitrification based on the presence of microorganisms associated with these processes.

Code

DOI: 10.1016/j.biortech.2017.07.183

Sources

Website PDF

See all publications 2017